Besplatna dostava Overseas kurirskom službom iznad 59.99 €
Overseas 4.99 Pošta 4.99 DPD 5.99 GLS 3.99 GLS paketomat 3.49 Box Now 4.49

Besplatna dostava putem Box Now paketomata i Overseas kurirske službe iznad 59,99 €!

Reference dosimetry of HDR Ir-192 sources using radiochromic film

Jezik EngleskiEngleski
Knjiga Meki uvez
Knjiga Reference dosimetry of HDR Ir-192 sources using radiochromic film Saad Aldelaijan
Libristo kod: 06842970
Nakladnici VDM Verlag, lipanj 2011
Over the years, film dosimetry was developed into a powerful 2D high resolution tool for radiotherap... Cijeli opis
? points 165 b
65.50
Vanjske zalihe Šaljemo za 15-20 dana

30 dana za povrat kupljenih proizvoda


Moglo bi vas zanimati i


Teaching the Very Able Child Belle Wallace / Meki uvez
common.buy 33.60
Proverbs Irving L. Jensen / Meki uvez
common.buy 11.46
Bol'she tröh ne sobirat'sq! Aleksey Terent'ev / Meki uvez
common.buy 75.27
William Huskisson and Liberal Reform Alexander Brady / Meki uvez
common.buy 64.40
The Development of the Finnish Banking Industry Ilkka Lähteenmäki / Meki uvez
common.buy 78.79
Screening in Disease Prevention Susie Stewart / Meki uvez
common.buy 41.15
Cognitive Load Theory Fred Paas / Meki uvez
common.buy 77.68
Police Michael Kennedy / Meki uvez
common.buy 87.24
Risque Pluvial En Milieu Urbain Florent Renard / Meki uvez
common.buy 158.29
Lament for a Lady Laird (Paper Only) Matthew Arnold / Tvrdi uvez
common.buy 19.92
Biographiearbeit mit älteren Menschen Saskia Semmer / Meki uvez
common.buy 59.16
Rescued Lives Karen J. Foli / Tvrdi uvez
common.buy 211.13

Over the years, film dosimetry was developed into a powerful 2D high resolution tool for radiotherapy treatment verification and quality assurance. Introduction of the radiochromic film, that has all the advantages of film dosimetry without the need for wet processors, makes this film type a very important dosimetric tool. It has properties equivalent to those of water and has been shown to have a response independent of beam quality in a broad energy range which makes it a suitable candidate for dosimetry in both standard and non standard beams. It is desirable to use the latest EBT-2 GAFCHROMIC film model in the dosimetry of high dose rate (HDR) Ir-192 sources in water which would provide direct absorbed dose comparison to the current reference dosimetry protocol for brachytherapy (TG-43 and its update). Also, it would be advantageous to perform these dosimetry measurements in a more convenient Solid Water medium which is less experimentally cumbersome and link the absorbed dose to Solid Water to the absorbed dose to water using a simple correction factor.

Informacije o knjizi

Puni naziv Reference dosimetry of HDR Ir-192 sources using radiochromic film
Jezik Engleski
Uvez Knjiga - Meki uvez
Datum izdanja 2011
Broj stranica 132
EAN 9783639360653
ISBN 3639360656
Libristo kod 06842970
Nakladnici VDM Verlag
Težina 204
Dimenzije 152 x 229 x 8
Poklonite ovu knjigu još danas
To je jednostavno
1 Dodajte knjigu u košaricu i odaberite isporuku kao poklon 2 Zauzvrat ćemo vam poslati kupon 3 Knjiga dolazi na adresu poklonoprimca

Prijava

Prijavite se na svoj račun. Još nemate Libristo račun? Otvorite ga odmah!

 
obvezno
obvezno

Nemate račun? Ostvarite pogodnosti uz Libristo račun!

Sve ćete imati pod kontrolom uz Libristo račun.

Otvoriti Libristo račun